Regional Train TALENT 2®
Battery Charger for Rail Applications
|
|
Customer: Bombardier Transportation
Number of Units: Framework Contract TALENT 2® | | | | Specifications | AC Input Voltage |
Frequency |
AC Nominal Power |
DC Output Voltage |
DC Output Power | | 3 x 400 V AC |
50 Hz ± 2% |
– |
110 V DC |
15 kW | |
Hamburg / Germany
DC/AC-DC Auxiliary Power Unit, Water Cooling
|
|
Customer: Bombardier Transportation
Number of Units: 54 | | | | Specifications | DC Input Voltage |
AC Output Voltage |
AC Nominal Power |
DC Output Voltage |
DC Output Power | | 750 V DC |
3 x 400 V AC/ 50 Hz 3 x 460 V AC/ 40 – 60 Hz |
40 kVA |
24 V DC |
10 kW | |
HVAC Inverter “Coolcon”
Webasto People Mover, integrated into HVAC unit
|
|
Customer: Webasto Product Italy S.p.A.
Number of Units: 160 | | | | Specifications | DC Input Voltage |
AC Output Voltage |
AC Nominal Power |
Frequency |
DC Output Power | | 750 V DC |
3 x 380 V AC |
25 kVA |
6 … 100 Hz |
– | |
Vancouver / Canada
DC/AC-AC-DC Auxiliary Power Unit for SkyTrain Vancouver II:
|
|
Customer: Bombardier Transportation
Number of Units: 48 | | | | Specifications | DC Input Voltage |
AC Output Voltage |
AC Nominal Power |
DC Output Voltage |
DC Output Power | | 600 V DC |
3 x 230 V 1 x 120 V |
40 kVA 2,4 kVA |
48 V DC |
15 kW | |
Metro Mexico City
DC/AC Inverter, Kompressor Application, Convectional Cooling
|
|
Customer: Kaeser Compresores
Number of Units: 327 | | | | Specifications | DC Input Voltage |
AC Output Voltage |
AC Nominal Power |
Frequency |
DC Output Power | | 750 V DC |
3 x 380 V AC |
15.5 kVA |
60 Hz |
– | |
Nuernberg / Germany
DC/AC-DC converter for Rubin DT3 subway, convectional cooling
|
|
Customer: Siemens Transportation Systems
Number of Units: 60 | | | | Specifications | DC Input Voltage |
AC Output Voltage |
AC Nominal Power |
DC Output Voltage |
DC Output Power | | 750 V DC |
400 V AC3 |
18 kVA |
110 V DC |
12 kW | |
CERN
Power supply for superconducting magnets for the European Laboratory for Particle Physics CERN in Switzerland
|
|
Customer: CERN
Number of Units: 50 units of ype ± 600A 18 units of type 13 kA 1 unit of type 20.5 kA | | | | Specifications | Input Voltage |
AC Output Voltage |
DC Output Voltage |
Output Ripple |
Output Power |
Cooling | | 400 V AC3 |
± 600 A |
± 40 V |
max. 10 mVpp |
24 kW |
Water |
| 400 V AC3 |
13000 A |
0...18 V |
max. 10 mVpp |
234 kW |
Water |
| 400 V AC3 |
20500 A |
0...18 V |
max. 10 mVpp |
369 kW |
Water | |